VENUS KR Plus Rack Mount 1-10kVA

Description

Model Rack mount (Standard UPS) KR1000PR KR2000PR KR3000PR KR5000PR KR6000PR KR1110PR
Rack mount (Long backup UPS) KR1000PRL KR2000PRL KR3000PRL KR5000PRL KR6000PRL KR1110PRL
CAPACITY For computer load (VA / W) 1000/900 2000/1800 3000/2700 5000/4500 6000/5400 10000/8000
SYSTEM Controller Intelligent UPS with DSP control
Technology High Frequency Double Conversion, Power Factor Control(PFC) with IGBT Technology
INPUT Voltage 220 Vac Single phase nominal voltage 220 Vac Single phase nominal voltage
Voltage range 220Vac: -45% to +35% 220Vac: -35% to +25%
Frequency 50/60 Hz ±6% (auto detect) at nominal voltage (±10% option)
Power factor >0.99 at full load(THDi<5%)
OUTPUT Voltage 220Vac ±1%(L-N+PE)
Phase Single phase (50/60Hz)
Frequency Normally locked to line frequency, Free running 50Hz ±0.1% (Crystal control)
Wave form Pure sine wave
Harmonic distortion <2% at full load ( Linear load ), <5% at full load (Non linear load)
Transient condition ±5% for 100% instantaneous load variation( STEP LOAD)
Overload capability 130% for 60 sec., 150% for 30 sec., >150% for 300ms, automatic transfer to Bypass 125%for10min., 150%for1min.,>150%for1sec., automatic transfer to Bypass
Crest factor 3:1
Protection Over / Under Voltage,Overload, Shot Circuit, Over Temp. and Battery Low Voltage Shutdown
EFFICIENCY DC to AC Approximate ≥ 87% Approximate ≥ 92%
AC to AC Approximate ≥ 92% Approximate ≥ 95%
BATTERY Type SLA : Seal Lead Acid Battery(maintenance-free) Rechargeable
Capacity 3×12V 9.4 Ah 4×12V 9.4Ah 6×12V 9.4Ah 16×12V 9.4 Ah
Voltage 36Vdc 48Vdc 72Vdc 192Vdc
Standard backup time 15-30 min. (Depend on computer load)
Extend backup time Option
Recharge time 6-8 hours to 90% after load discharged
Charger Current(A) Standard – 1A / Long Backup – 4A Standard-1A/LongBackup:1-8A Adjustable
Battery temperature compensation for recharge Option
TRANSFER TIME Main fail or Recover UPS to by pass and vice versa Zero time (True On-line UPS)
INDICATOR Front panel LED Line, Inverter, Bypass, Battery, L-N input warning and Fault
Front panel LCD Input / Output Voltage, Frequency, Battery Voltage, % Load, Temperature and UPS status
PROTECTION EMI/RFI attenuation >40 dB
Surge protection UL recognized surge protection to std.1449
Surge energy dissipation 220 Joules (510 Joules option)(2 microsec wave form)
AUDIBLE ALARM Multiple tones with reset for silence Mains Failure, Low battery, Overload and UPS fault
INPUT PLUG Power cord 1.5 meter NEMA 5-15P Terminal
OUTPUT OUTLET Rack mount 3 – 4xNational (Terminal option) Terminal
COMMUNICATION INTERFACE DB-9 connector RS-232 serial port can be connected to PC, workstation or servers for automatic unattended shutdown and EPO & ECO (Option)
Software UPSilon2000 supported for windows 95, 98, NT, 2000, Me, XP, Novell Netware Linux, FreeBSD (IBM, Sun, Solaris option)
SNMP/HTTP capability. SNMP Card, AS400 Card – Dry Contact, GPRS Modem, Environment
ACOUSTIC NOISE At 1 meter < 50 dBA < 55 dBA
ENVIRONMENT Temperature 0-45°C
Humidity 0-95 % (Non-Condensing)
DIMENSIONS

(W×H×D) mm.

Standard UPS Rack 19 inch 440 × 88 × 420 ( 2U ) 440×88×500(2U)
Long backup UPS Rack 19 inch 440 × 88 × 420 ( 2U ) 440×88×500(2U)
Battery Unit for UPS 440×88×420(2U)(Batt6-8PCS) 440 × 130 × 500 (3U) (Batt 16PCS)
WEIGHT

(approximate in Kg.)

Standard UPS 13(+Batt) 8 8 11 12.5
Long backup UPS 7 8.5 8.5 11 12.5
Battery Unit for UPS 8 / 14 13 18 45 (Batt 16PCS)
CONFORMANCE Design regulation TIS.1291 Part1-2553, Part2-2553, Part3-2555 : C1
CE : EN 62040-1: LVD, IEC 62040-2 : EMC, IEC 62040-3 Performance, UL no.E337869