VENUS ULTIMATE 33 10-40kVA

VENUS ULTIMATE 33 10-40kVA

DSP TRUE ONLINE DOUBLE CONVERSION UPS

Advance DSP Control Technology The advance DSP digital control technology enable UPS more stable performance and with battery quality.

 

Active Input Power Factor Correction (PFC) Digitalized control of the PFC enable the UPS to keep the Input power factor above 0.99 to prevent possible electric grid pollution and meanwhile mostly save the cost.

 

Wide Input and Frequency Range We intentionally widen the range of input factors to make sure the UPS can apply to various environment, which will Effectively sustain the battery charging even in unstable power environment so that the service life of the UPS could be obviously prolonged.

Description

Venus Ultimate 33 10-40kVA

DSP TRUE ONLINE DOUBLE CONVERSION UPS

Advance DSP Control Technology The advance DSP digital control technology enable UPS more stable performance and with battery quality.

 

Active Input Power Factor Correction (PFC) Digitalized control of the PFC enable the UPS to keep the Input power factor above 0.99 to prevent possible electric grid pollution and meanwhile mostly save the cost.

 

Wide Input and Frequency Range We intentionally widen the range of input factors to make sure the UPS can apply to various environment, which will Effectively sustain the battery charging even in unstable power environment so that the service life of the UPS could be obviously prolonged.

 

Adaptive Load Management This technology allows the UPS to be set up at a fixed 50HZ or 60HZ output while it also can intelligently monitor power usage and automatically sheds and reconnects loads in order to prevent generator overload.

 

 

Support the Generator The wide range of input voltage and frequency can effectively separate the harmful electric wave produces the generators and provide safe and reliable power supply.

High-reliability Parallel Redundancy Technology N+X parallel redundant technology means that there is a UPS unit providing protection for the key loads. When any one of the system was failure, the UPS could provide the high quality power to the key loads due to the additional one, which makes the system more reliable.

 

 

Features

  • True On-line Double Conversion UPS
  • Advance Digital DSP control and IGBT technology High input Power Factor Correction PFC>0.99
  • Low Input Current Harmonic THDI <5% Output Pure Sine Wave THDV <3% Wide Input Voltage / Frequency Range (208 -478Vac) Included Battery (10-20KVA) / Long Backup (30-40KVA) Output Power Factor PF0.9
  • AC & DC Cold Start function
  • Easy Interface LED & LCD Panel with Function Switch
  • Built in Static Transfer Switch (SCR)
  • Advanced Battery Management (ABM)
  • Intelligent Forced wind (Fan speed control)
  • Economy mode (ECO : option)
  • Emergency Power Off (EPO:option)
  • Fully Protection Function
  • USB communication port, with UPSilon 2000 Monitoring
  • SNMP/HTTP Capability/ Dry Contact, Modbus (option)
  • Parallel Redundant N+X technology(option)
  • Intelligent Battery Monitoring system-MMBM (option)
  • TIS.1291 Part 1-2553, Part 2-2553, Part 3-2555: C3
  • Certificate CE : IEC62040-1,-2 ,-3, IEC55022, IEC61000
  • ISO9001:2015/ISO14001:2015 Certified Manufacture

 

Applications

Industrial Equipment

Postal & Telecommunications

Data Center & Server Room

Hospital, Medical Equipment

Large Internet Computer Room

Financial & Securities