Model S2.0 |
Standard UPS |
VNU1000 |
VNU2000E |
VNU2000 |
VNU3000 |
VNU5K / P |
VNU6K / P |
VNU10K / P |
Long backup UPS |
VNU1000L |
VNU2000EL |
VNU2000L |
VNU3000L |
VNU5KL / P |
VNU6KL / P |
VNU10KL / P |
CAPACITY PF=0.9 |
For Computer load |
1000VA/900W |
2000VA/1800W |
2000VA/1800W |
3000VA/2700W |
5000VA/4500W |
6000VA/5400W |
10000VA/8000W |
SYSTEM |
Controller |
Intelligent UPS with DSP controlled |
Technology |
High Frequency Online Double Conversion UPS with Power Factor Correction(PFC) IGBT Technology |
INPUT |
Voltage |
220Vac Single Phase nominal voltage(220/230/240Vac) |
Voltage Range |
220Vac: -40% to +35% 110-300 |
220Vac: -35% to +25% 120-276 |
Frequency |
50/60 Hz ±10% (Auto detect) at nominal voltage (±10% option) |
Power Factor |
PF >0.99 at Full Load |
OUTPUT |
Voltage |
220Vac ±1% / (200/208/220/230/240 adjusted by key switch front panel and software) |
Phase |
Single Phase(L-N+PE) |
Frequency |
Normally locked to line frequency, Free running 50Hz ±0.1%/(60 Hz adjusted by switch front panel and software) |
Wave Form |
Pure Sine Wave |
Harmonic Distortion |
THDv <3% at Linear Load |
Transient Condition |
±5% for 100% instantaneous load variation (Step Load) |
Overload Capability |
120% for 60 sec., 150% for 30 sec., >150% for 300ms |
120% for 2min., 150% for 30sec., >150% for 1sec. |
Crest Factor |
3:1 |
Protection |
Overvoltage, Under voltage, Overload, Shot circuit, Over temperature and Battery low voltage shutdown |
EFFICIENCY |
DC to AC |
Approximate ≥ 85% |
Approximate ≥ 90% |
AC to AC |
≥ 89% at Full Linear Load |
≥ 93% at Full Linear Load |
BATTERY |
Type |
Seal Lead Acid (Maintenance-free) Rechargeable Battery |
Capacity |
3x12V7.5Ah |
6x12V 7.5Ah |
8x12V 7.5Ah |
20x12V 7.5Ah |
20x12V 9.4Ah |
Voltage |
36Vdc |
72Vdc |
96Vdc |
240Vdc |
Standard Backup Time |
15-30 min. (Depend on Computer Load) |
Extend Backup Time |
Battery Unit Option |
Recharge Time |
6-8 hours to 90% after load discharged |
Charger Current(A) |
Standard 1A / Long Backup 6A |
Standard 1A / Long Bacukup 10A(Adjust) |
TRANSFER TIME |
Main fail or Recover UPS to by pass and vice versa |
Zero Transfer Time , Static Transfer Switch (SCR) |
INDICATOR |
Front Panel LED |
Line, Inverter, Bypass and Battery |
Front Panel LCD |
Operate status, Input voltage, Output voltage, Frequency, Bypass, Battery voltage, % Battery, % Load, VA, Watt, Temperature and Fault, Remaining battery backup time |
PROTECTION |
EMI/RFI Attenuation |
>40 dB |
Surge Protection |
UL recognized surge protection to std.1449 |
Surge Energy Dissipation |
220 Joules (510 Joules option)(2 microsec wave form) |
AUDIBLE ALARM |
Multiple Tones with Reset for Silence |
Mains Failure, Low battery, Overload and UPS fault |
INPUT PLUG |
Power Cord 1.5 meter |
NEMA 5-15P (IEC 320, GS option) |
Terminal |
OUTPUT OUTLET |
Universal Plug |
3 x National |
4 x National |
Terminal |
COMUNICATION INTERFACE |
USB |
USB port can be connected to PC, workstation or servers for automatic unattended shutdown |
Software |
UPSilon2000 or WinPower for windows Me, XP, 7, 8, 10, Novell Netware, Linux, FreeBSD (IBM, Sun, Solaris option) |
optional |
SNMP Card(Network), AS400 Card(Relay Dry Contact) Parallel Card |
ACOUSTIC NOISE |
At 1 meter |
< 45 dBA |
< 50 dBA |
ENVIRONMENT |
Temperature |
0-40oC |
Humidity |
0-95 % (Non-Condensing) |
DIMENSIONS (WxHxD) mm |
UPS include standard battery |
145x220x400 |
191x336x470 |
250x616x502 |
Long backup UPS |
145x220x400 |
191x336x470 |
250x616x502 |
Battery Unit extension (option) |
Separate (UPS and battery extension rack) |
WEIGHT (approximate in Kg.) |
UPS include standard battery |
13 |
25 |
29 |
30 |
62 |
64 |
Long Backup UPS |
6.0 |
11 |
12 |
12 |
18 |
20 |
Battery Extension Unit (option) |
Depending on battery capacity |
CONFORMANCE |
Design regulation |
TIS.1291 Part1-2553, Part2-2553, Part3-2555 : C1, CE:IEC62040-1, -2, -3, IEC55022, IEC61000 |
TIS.1291 Part1-2553, Part2-2553, Part3-2555 : C1, CE:IEC62040-1, -2, -3, IEC55022, IEC61000 |