without battery |
TDX3310i |
TDX3315i |
TDX3320i |
TDX3330i |
TDX3340i |
TDX3350i |
TDX3360i |
with battery |
TDX3310is |
TDX3315is |
TDX3320is |
TDX3330is |
|
|
|
Power (VA/W) |
10kVA / 9kW |
15kVA / 13.5kW |
20kVA / 18kW |
30kVA / 27kW |
40kVA / 36kW |
50kVA / 45kW |
60kVA / 54kW |
Technology |
DSD True Online Double Conversion with Isolation Transformer |
Input Power Factor |
High Power Factor Corrector PFC >0.99 |
Rectifier Type |
3Level IGBT Rectifier THDi<5% |
INPUT SYSYTEM |
|
Voltage System |
3phase 4wire+PE (3phase 3wire+PE option) |
Voltage |
L-N / L-L:220 / 380VAC -50% / +25% (115 / 200, 120 / 208, 230 / 400, 240 / 415 option) |
Frequency |
50 / 60 Hz +/-10% |
Soft Start |
0-100% in 5sec |
BYPASS SYSTEM |
|
Phase |
3phase 4wire+PE (3phase 3wire+PE option) |
Voltage |
L-N/L-L : 220/380VAC (115/200,120/208,230/400,240/415 option) |
Transfer Time |
0ms : Zero Transfer |
CHARGER SYSTEM |
|
Charger Mode |
384VDC : Tri-State Charger (Buck, Boost, Float) |
Float Voltage |
384VDC : 432-411.6VDC |
Boost Voltage |
384VDC : 454.4-464VDC |
Battery Charge Current |
10-25A setting |
10-40A setting |
OUTPUT SYSTEM |
|
Phase |
3phase 4wire+PE (3phase 3wire+PE option) |
Voltage |
L-N / L-L : 220 / 380VAC +/-1% (115 / 200, 120 / 208, 230 / 400, 240 / 415 option) |
Frequency |
50Hz/60Hz +/-0.1% |
Wave Form |
Pure Sine Wave |
Unbalance load Voltage |
2% compatible 100% Load Unbalance |
Total Harmonic Distrotion |
THDv <2% at Full Load (Linear Load), <5% at Full Load (Non Linear Load) |
Smart ECO Efficiency |
up to 98% |
Transfer Time |
0ms : Zero Transfer |
Power Factor |
PF0.9 (PF1.0 Option) |
Over Load |
105% Load for Continuity, 106%-125% Load for 10 mins, 126%-150% Load for 1 min >150 Load for 500 ms |
BATTERY |
|
Battery Type |
AGM / SLA : Sealed Lead Acid (Maintenance Free) Battery (Option : UL94-V0) |
Battery Capacity |
32x12V7.5Ah |
64x12V7.5Ah |
64x12V7.5Ah |
64x12V9.4Ah |
External Batterry Unit |
Battery Voltage |
384Vdc/32Pcs (360/372/384Vdc : 30/31/32Pcs |
Backup Time |
5min at Full Load |
Extend Backup Time |
6-120 min |
Battery Self-Testing |
Automatically Alarm and Estimate Battery in battery abnormal status |
PROTECTION SYSTEM |
|
Input Protection |
Input Voltage / Frequency Over limited, Wrong phase, Lack phase |
Output Protection |
Over Current, Short Circuit, Output Over / Under Voltage |
Battery Protection |
Over Charge, Over-Discharge Protection |
Temperature Protection |
Ambient over-temperature protection, inverter over-temperature protection |
Maintenance Bypass |
MCB Bypass |
Alarm |
Overload, Abnormal AC input, low battery, UPS Failure |
INDICATOR |
|
LCD Display & ICON(HMI) |
Main input, Rectifier, Inverter, Bypass, Maintenance bypass, Battery, Bypass static, Inverter static,Output, Main input voltage display, Battery voltage display, Output voltage display/Load percentage, Menu |
COMMUNICATION |
|
Intelligent Port |
RS232/RS485, Parallel card interface, Dry Contact, (MODBUS and SNMP adapter are optional) |
ENVIRONMENT |
|
Audible Noise |
<65dB |
Temperature |
0°C – 40°C |
Humidity |
0%-95% (Condensing) |
STANDARD |
|
Safety / EMC / Performance |
TIS.1291 : Part1-2553, Part2-2553, Part3-2555 C3 / CE : IEC62040-1, -2, -3, IEC55022, IEC61000 |
Manufacturer QMS |
ISO9001 : 2015 / ISO14001 : 2015 |
Dimension (W x D x H) mm. |
480x900x1200 |
800x800x1600 |
Weight with out Batt / with Batt (Kg.) |
323/403 |
353/513 |
373/533 |
393/553 |
450 |
470 |
490 |